400G QSFP-DD DR4

400G QSFP-DD DR4

400GBASE-DR4 QSFP-DD PAM4 Silicon Photonics Transceiver Module Dab tsi yog 400G-DR4 Cov khoom no yog 400Gb/s QSFP-DD optical module tsim los rau 0.5Km optical kev sib txuas lus daim ntawv thov. Lub module hloov 8 raws ntawm 50Gb / s (PAM4) cov ntaub ntawv hluav taws xob nkag mus rau 4 raws ntawm cov kab sib txuas ntawm qhov muag pom, ...

  • Khoom Taw qhia

 

400G QSFP-DD DR4 Optical Transceiver

 

High-kev ua tau zoo 400GBASE-DR4 module nrog Silicon Photonics thev naus laus zis. Txhawb 500m SMF kis tau tus mob thiab 4 × 100G breakout muaj peev xwm. Qhov zoo tshaj plaws rau hyperscale cov chaw zov me nyuam thiab AI / GPU pawg sib cuam tshuam.

  • 425G Ceev tshaj plaws
  • 500M Qhov siab tshaj plaws
  • <10W Typical Power Consumption

 

 

400G QSFP-DD DR4 Optical Transceiver

 

Khoom Taw Qhia

 

Kev lag luam- ua thev naus laus zis rau siab - ceev cov ntaub ntawv chaw sib txuas

400G QSFP-DD DR4 DSP Chip

Siab -Kev Ua Haujlwm DSP Chip

Ua-hauv Broadcom 7nm DSP nrog lub zog siv qis dua 10W, txo qis cov nqi hluav taws xob hauv cov ntaub ntawv.

Silicon Photonics Technology

Silicon Photonics Technology

Advanced 300mm wafer CMOS process with >85% yield tus nqi. Kev sib xyaw ua ke siab dua thiab cov nqi tsim khoom qis dua.

4×100G Breakout Support

4 × 100G Breakout Txhawb

Hloov pauv hloov mus rau 4 × 100G-DR interfaces lossis 2 × 200G-DR2 rau kev hloov kho txuas ntxiv thiab kev tiv thaiv peev.

500m SMF Transmission

500m SMF kis tau tus mob

Ua tau raws li hauv -data center interconnect xav tau. Zoo meej rau tus txha caj qaum-Leaf architecture siab- kev sib txuas ceev.

Full Standards Compliance

Tag Nrho Cov Qauv Ua Raws Cai

Ua raws li IEEE 802.3bs, QSFP-DD MSA CMIS Rev4.1, OIF CEI-56G-VSR-PAM4, thiab 100G Lambda MSA.

Multi-Brand Compatibility

Ntau -Brand Compatibility

Kuaj thiab txheeb xyuas tau tshaj Cisco, Arista, Juniper, Dell, Huawei, HPE, NVIDIA/Mellanox khoom.

 

Ntsiab Specifications

425gbps ua
Max Data Rate
(4 × 106.25Gb/s PAM4)
500m
Kev sib kis
Qhov deb (SMF)
<10W
Hwj chim
Kev noj haus
MPO-12
APC
Txuas

 

Specifications

Tshooj Naj Npawb QDD-DR4-400G Tus neeg muag khoom npe FB -LINK
Form Factor QSFP-DD Max Data Rate 425Gbps (4x106.25Gb/s)
Lub wavelength 1310nm ua Max Kab nrug deb 500m
Txuas MTP/MPO-12 Media SMF
Hom Transmitter DFB Hom txais PIN
Tx Power -2.9 ~ 4.0dBm Rx zog -5.9 ~ 4.0dBm
Kev siv fais fab Tsawg dua lossis sib npaug li 10W Extinction Ratio 3.5dB ua
Powerbudget 3dB ib Modulation 8x50g 4

 

 

Compatibility & Platform Txhawb

FB-LINK 400G QSFP-DD DR4 modules tau kuaj tag nrho thiab txheeb xyuas tau zoo nrog cov kev sib txuas lus loj:

 

Certified Hloov Compatibility

Hom Tau tshaj cov qauv Min. Software Version
Cisco Nexus 9316D-GX, 9332D-GX, 93600CD-GX, 9408, 9500 w/400G kab phaib, Catalyst 9500 NX-OS 10.2(1)+, IOS-XE 17.x+
Arista 7800R3-36P-LC, 7800R3-36D-LC, 7500R3-24P-LC, 7280R3-24, 7280CR3-32P4 EOS 4.25.x+
Juniper QFX5220-32CD, QFX5220-128C, QFX5230, QFX5240, PTX10001-36MR, PTX10003, PTX10008 Junos Evolved 21.2R 1+
Dell EMC PowerSwitch S5448F-ON, Z9332F-ON, Z9432F-ON, Z9664F-ON OS10 10.5+
HPE/Aruba CX 9300-32D, CX 9300S, CX 10000 AOS -CX 10.11+
Huawei CloudEngine CE9860-4C-EI/HI, CE8800, CE6800 V200R020C00+
NVIDIA/Mellanox Spectrum-3 SN4700, Spectrum-4 SN5400/5600/5800 Cumulus/SONiC
Ntug -Core AS9716-32D, AS9726-32DB, AS9737-32DB ONIE/SONIC

 

NIC Interoperability

NCO Model Interface Txoj kev sib txuas
NVIDIA ConnectX-7 (OSFP) OSFP 400 G Optical interop (tib yam DR4 tus qauv)
Broadcom BCM57608 QSFP112 400G Direct optical interop
Intel E810 (100GbE) QSFP28 100G 4 × 100G Breakout

 

Breakout Configurations

Kev teeb tsa Far{0}}end Module Max nrug Yuav tsum tau Cable
4 × 100G-DR1 QSFP28 100G-DR 500m MPO-12 rau 4 × LC Duplex
4 × 100G-FR1 QSFP28 100G-FR 500m* MPO-12 rau 4 × LC Duplex
2 × 200G-DR2 QSFP56-DD 200G-DR2 500m MPO-12 lub cev

 

* Qhov deb txwv los ntawm luv dua - mus txog module

 

QSFP-DD compatibility

 
 

FB-LINK tsim thiab tsim 100G QSFP28, 200G QSFP56, 400G QSFP112, 400G OSFP, thiab 800G OSFP.

ARISTA
CISCO
H3C
HUAWEI
ZTE
Alcatel-Lucent
JUNIPER
Mikrotik
Intel
HP

Kuaj nyob rau hauv Cov Cuab Yeej Cuab Yeej rau Kev Tshawb Fawb Kev Ua Haujlwm

Txhua chav tsev yog kuaj zoo rau kev sib raug zoo hauv qhov chaw hloov pauv, uas lav kev ua haujlwm tsis zoo.

Tested in Host Devices for Proven Interoperability

 

Daim ntawv thov Scenario

Los ntawm hyperscale cov chaw zov me nyuam mus rau lub tsev kawm ntawv kev lag luam, ntsib ntau haiv neeg siab -kev sib txuas ceev xav tau.

Hyperscale Data Center Interconnect

Siab-kev sib tshuam ceev ceev ntawm tus txha caj qaum hloov hauv qaum- Nplooj architecture. Txhawb 36-port/1U siab-kev xa tawm ceev. Qhov kev ncua deb: 100m-500m. Qhov zoo tshaj plaws rau cov chaw muab kev pabcuam huab tsim loj sab hnub tuaj-west bandwidth infrastructure.

01

AI & GPU Cluster Networking

Kev sib txuas rau NVIDIA DGX H100 / H200 / B200, AMD MI300 AI servers. Txhawb NVIDIA Quantum-2 InfiniBand (NDR 400G) thiab Spectrum-4 Ethernet keyboards. Ultra-low latency rau kev faib cov txheej txheem kev cob qhia. Scales los ntawm 8-GPU nodes mus rau 10, 000+ GPU supercomputers.

02

100G rau 400G Network Hloov Kho

Leverage breakout muaj peev xwm rau kev nqis peev- kev txhim kho kev tiv thaiv. Nruab 400G DR4 nyob rau hauv tus txha nraub qaum hloov tshiab, txuas mus rau 100G QSFP28 DR modules uas twb muaj lawm los ntawm kev tawg cable, tom qab ntawd hloov kho 100G qhov chaw mus rau 400G raws li xav tau. Tsis tas yuav hloov kho forklift.

03

Enterprise Campus Backbone

Txuas cov tsev kawm ntawv hauv tsev kawm ntawv nrog siab - pob txha ceev . 500m ncav cuag feem ntau hauv tsev kawm ntawv. Tsawg fiber ntau suav dua FR4 (parallel vs. CWDM). Core hloov mus rau aggregation txheej siab - ceev interconnect. Yav tom ntej - pov thawj infrastructure rau 10+ xyoo.

04

 

Breakout Connectivity

Saj zawg zog Breakout Configurations

400G QSFP-DD DR4 txhawb nqa ntau qhov kev teeb tsa rau kev xa tawm yooj yim tshaj plaws:

 

4 × 100G-DR1:Far-end QSFP28 100G-DR|Max 500m|MPO-12 rau 4 × LC Duplex cable

4 × 100G-FR1:Far-kawg QSFP28 100G-FR|Max 500m *|MPO-12 rau 4 × LC Duplex cable

2 × 200G-DR2:Far-end QSFP56-DD 200G-DR2|Max 500m|MPO-12 lub cev cable

 

* Qhov deb txwv los ntawm luv dua - mus txog module

Pom zoo Cable:MTP / MPO-12 txog 4 × LC Duplex breakout thaj qaum

 

Dawb EEPROM Coding rau Seamless Integration

 

Peb muab kev cai pub dawb EEPROM coding kom paub meej seamless compatibility nrog koj cov khoom siv network:

 

Cisco- tshwj xeeb coding:QDD-400G-DR4-S

Arista - tshwj xeeb coding:QDD-400G-DR4-AR

Juniper- tshwj xeeb coding:QDD-400G-DR4

Dell/HPE/Huawei -cov coding tshwj xeeb:Muaj nyob ntawm kev thov

 

Lub sijhawm hloov pauv:1-2 hnub ua hauj lwm ntxiv

 

Thov Kev Cai Coding

 

Kev lag luam-Cov ntawv pov thawj pom zoo

ISA,High-tech Enterprise Certificate,CIRCLE Certification,SGS Certification,ISO 9001:2015,IAF

ROHS,ISO 14001,ISO 9001,CE

ISO 4001,ISO 9001,ISA,CIRCLE

FAQ Txog400G QSFP-DD DR4 Optical Transceiver

Q: Cov qauv no puas ua haujlwm nrog kuv lub Cisco lossis Arista hloov?

A: Yog. Nws ua haujlwm tawm - ntawm - lub - lub thawv nrog rau feem ntau lub lag luam hloov. Txhawm rau tshem tawm cov lus ceeb toom "tsis txhawb nqa transceiver", peb muab EEPROM coding pub dawb rau Cisco, Arista, Juniper, thiab lwm lub platforms-tsuas yog qhia rau peb paub koj tus qauv hloov thaum xaj.

Q: Tus nqi piv rau hom npe li cas -npe lwm txoj?

A: Cia siab tias 60-80% kev txuag nyiaj piv rau OEM- cov khoom sib npaug. Peb siv cov thev naus laus zis zoo ib yam Silicon Photonics thiab Broadcom DSP chips-tus nqi sib txawv los ntawm kev tshem tawm cov cim npe, tsis txiav qhov zoo.

Q: Dab tsi yog them raws li warranty?

A: 3-xyoo them rau qhov tsis xws luag thiab teeb meem kev ua haujlwm, ntxiv rau 30-hnub nyiaj rov qab lav. Txuas ntxiv 5-xyoo kev xaiv muaj rau kev xa khoom lag luam.

Q: Puas muaj qhov kev txiav txim yam tsawg kawg nkaus? Kuv tuaj yeem tau txais nws sai npaum li cas?

A: Tsis muaj MOQ- xaj txawm tias ib chav tsev rau kev ntsuas. Hauv -cov khoom xa tuaj hauv 1-3 hnub ua haujlwm. Cov nqi luv nqi pib ntawm 100+ units.

Q: DR4 vs FR4 vs LR4-uas kuv xav tau?

A: Nws nyob ntawm qhov deb. DR4 npog txog li 500m siv 4 parallel fibers -zoo tshaj rau intra-datacenter links. FR4 ncav cuag 2km ntawm 2 fibers ntawm wavelength multiplexing. LR4 txuas ntxiv mus rau 10km rau cov pob txha hauv tsev kawm ntawv. Rau feem ntau khib-rau- khib lossis kab-rau- kab sib txuas, DR4 muab tus nqi qis tshaj plaws thiab lub zog kos.

Q: Kuv puas tuaj yeem txuas qhov no rau kuv cov khoom siv 100G uas twb muaj lawm?

A: Yog lawm. Siv hom kev sib cais los faib ib qho 400G chaw nres nkoj rau hauv plaub qhov kev sib txuas 100G ntawm MPO-rau-LC cable. Qhov no tso cai rau koj hloov kho tus txha nraub qaum mus rau 400G thaum khaws cov nplooj hloov pauv ntawm 100G- tsis tas yuav hloov kho forklift.

Q: Dab tsi ua rau QSFP-DD txawv ntawm QSFP28?

A: Muab ob npaug rau txoj kab hluav taws xob-8 piv rau 4-ua kom 400G hauv qhov zoo sib xws. Lub connector yog rov qab sib xws, yog li koj tseem tuaj yeem siv QSFP28 modules hauv DD chaw nres nkoj ntawm qis dua.

Q: Vim li cas PAM4 tsis siv NRZ signaling?

A: PAM4 ntim 2 khoom rau ib lub cim (vs 1 me ntsis hauv NRZ), ua ob npaug ntawm kev xa tawm yam tsis tau muab ob npaug rau qhov kev taw qhia zaus. Qhov no ua rau cov khoom siv hluav taws xob pheej yig thaum ntaus 400G ceev. Lub built-hauv 7nm DSP ua haujlwm cov teeb liab ntxiv ntawm qis dua 10W.

Q: Kuv yuav nruab nws li cas?

A: Kub- sib pauv tus phooj ywg- tsis tas yuav muaj sijhawm poob. Ntxuav cov fiber ntau, xaub lub module kom txog thaum nws nyem, txuas koj MPO-12 cable, ua tiav. Auto-negotiation lis lwm tus. Rau hom kev tawg, teeb tsa qhov chaw nres nkoj li "4x100G" hauv koj qhov hloov CLI.

Q: Txuas qhov yuam kev lossis teeb liab tsis muaj zog -Kuv yuav tsum kuaj dab tsi?

A: Pib nrog cov hauv paus ntsiab lus: cov khoom siv qias neeg (ntxuav nrog lint- cov ntaub so dawb), hom fiber ntau tsis raug (yuav tsum yog tib hom -} hom), lossis ntau lub vojvoog khoov. Xyuas kom tseeb tias qhov txuas yog qis dua 500m thiab koj lub firmware hloov pauv tau raws li qhov tsawg kawg nkaus ntawm peb daim ntawv teev npe sib raug. Tshawb xyuas Tx/Rx lub zog ntawm CLI- nyeem tsis zoo taw tes rau cov teeb meem cable lossis connector.

 

Cim npe nrov: Optical Transceivers

Xa kev nug

(0/10)

clearall